Inspection History Details
Inspection Status: Canceled
Inspection History: RSBU - Building Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2022 | RSBU - Building Final | Canceled | Inspection Canceled | |
| 05/29/2024 | RSBU - Building Final | Re-inspection required | 5/29/24: mini splits are being over Amped, disconnect boxes required at mini splits, properly terminate condensate lines 6" above grade, sediment trap required at water heater, tape must be removed at water heater vent, exterior receptacles must be WR, smoke alarms must be interconnected, water hammer arrestors missing at laundry, GFCI request disposal, clean out cap required at exterior, anti-tip at range missing, seal all penetrations going through vapor barrier, arc-fault breaker's missing throughout, panel schedule must be area specific. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. | |
| 09/11/2024 | RSBU - Building Final | Canceled | 5/29/24: mini splits are being over Amped, disconnect boxes required at mini splits, properly terminate condensate lines 6" above grade, sediment trap required at water heater, tape must be removed at water heater vent, exterior receptacles must be WR, smoke alarms must be interconnected, water hammer arrestors missing at laundry, GFCI request disposal, clean out cap required at exterior, anti-tip at range missing, seal all penetrations going through vapor barrier, arc-fault breaker's missing throughout, panel schedule must be area specific. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. 9/11/24: Canceled per Juan. |
|
| 11/05/2024 | RSBU - Building Final | Canceled | 11/5/2024. Canceled per Juan. | |
| 12/13/2024 | RSBU - Building Final | Passed |