Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - LCBU - Excavation/Rebar/Zoning
Permit Number - T21CM07041
Inspection Description - COT - LCBU - Excavation/Rebar/Zoning
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - LCBU - Excavation/Rebar/Zoning | Not Ready | ||
| 10/07/2022 | COT - LCBU - Excavation/Rebar/Zoning | ESTEVENS | Partial Approval | Entered by NGARCIA3 - Partial . West side loading dock footing and east side loading dock wall. |
| 10/05/2022 | COT - LCBU - Excavation/Rebar/Zoning | IVR USER | Cancelled | Entered by IVR USER - IVRS - RI canceled |
| 09/29/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Partial Approval | Entered by NGARCIA3 - pa East loading dock ok to pour |
| 08/18/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Partial Approval | Entered by NGARCIA3 - pa Ok to pour tilt ups 23-28 |
| 08/16/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Partial Approval | Entered by NGARCIA3 - pa Panels 13 to 22 ok to pour. |
| 08/12/2022 | COT - LCBU - Excavation/Rebar/Zoning | SCARRAZCO | Partial Approval | Entered by VVERA1 - Partial. 1-12 panels are okay to pour. |
| 08/10/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Cancelled | Entered by VVERA1 - ca Per Chuck |
| 07/28/2022 | COT - LCBU - Excavation/Rebar/Zoning | ESTEVENS | Partial Approval | Entered by NGARCIA3 - Partial. Building slab complete. |
| 07/26/2022 | COT - LCBU - Excavation/Rebar/Zoning | SCARRAZCO | Partial Approval | Entered by RSALDAT1 - grid line 6 to 9. Column 6 to 9 north to south and A to X East to west. |
| 07/22/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Partial Approval | Entered by VVERA1 - pa Footings in mid section - GL 12 - 9 East to West - ok to pour |
| 06/22/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Partial Approval | Entered by VVERA1 - pa Stems ok to pour at F-U/2.2-1 and D-F/1-0.5 |
| 06/15/2022 | COT - LCBU - Excavation/Rebar/Zoning | TGAUSP | Partial Approval | Entered by VVERA1 - Partial, per special inspection reports, okay for concrete placement |
| 05/24/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Partial Approval | Entered by NGARCIA3 - pa Interior column footings - J- 2-13 and R- 4- 19 - ok to pour |
| 05/24/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Partial Approval | Entered by NGARCIA3 - pa Interior column footings - J- 2-13 and R- 4- 19 - ok to pour |
| 05/04/2022 | COT - LCBU - Excavation/Rebar/Zoning | DQUINN | Partial Approval | Entered by VVERA1 - pa GL 17-14 J-R. 8 column pad footings ok to pour. |
| 11/07/2022 | COT - LCBU - Excavation/Rebar/Zoning | Partial Pass | for 2 light pole footings, conduits and ufers. | |
| 11/16/2022 | COT - LCBU - Excavation/Rebar/Zoning | Partial Pass | partial approval for retainer footer, NW side for handicap ramp and stair at man door, ok to place concrete |