10/26/2022 COT - LCPL - Plumbing Final  Not Ready
09/07/2021 COT - LCPL - Plumbing Final  DBENOIT Prior to Final Inspectn Entered by DBENOIT1 - WATER CHLORINATION REPORT REQUIRED PRIOR TO FINAL INSPECTION
08/03/2023 COT - LCPL - Plumbing Final  Re-inspection required 8/3/23: 1. Install permanent address numbers. 2. Clean and remove all construction debris front & rear. 3. ADA horizontal grab bar exceeds 36" max from floor. 4. Water closet exceeds 18" from wall. 5. Install toilet paper holder per plan. 6. Wrap drain pipes & water lines under sink. 7. Mirror exceed 40" from floor. 8. Submit water chlorination report thru portal. 9. Install all door hardware. 10. Waiting on Fire Dept final. 11. Identify all roof mounted units per panel schedule and verity correct fuse for each unit.
08/28/2023 COT - LCPL - Plumbing Final  Passed