Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date |
Description |
Inspector |
Results |
Comments |
| 08/17/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
Approved |
| 02/24/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial, top course bond beam, okay to grout all building walls |
| 02/23/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial approval for the 6th and final lift at all building walls. Partial for (4) canopy bases |
| 02/17/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial for the 4th lift on the west, east and north walls (20’) Okay to grout progress areas |
| 02/16/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Cancelled |
Cancelled by Contractor (rain) |
| 02/15/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Not ready for Inspection |
NR, rescheduled for next day |
| 02/14/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial for the 3rd lift on the east and north walls (15’) Okay to grout progress areas |
| 02/11/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Cancelled |
- cancelled by Contractor |
| 02/10/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial for the 3rd lift on the west and north walls (15’) Okay to grout progress areas |
| 02/09/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial for the 2nd lift on the north and east walls (10’) Okay to grout progress areas |
| 02/08/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial, second lift North side ok for grout. |
| 02/02/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
PARTIAL FRONT BUILDING final lift 26’-6” ok to grout. |
| 01/31/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial, 5th lift to 23’-6” ok to grout progress areas. |
| 01/26/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial, continued 4th lift for South West elevation ok to grout and proceed. |
| 01/25/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial for 4th lift (28’) from east end column line 1-2.5, all south end, ending at west end column line 3. |
| 01/21/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
Partial for 3rd lift (15’) from east end column line 1-2.5, all south end, ending at west end column line 3 |
| 01/19/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
- Partial for 2nd lift (10’) from east end column line 1-2.5, all south end, ending at west end column line 3 |
| 01/12/2022 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
- Partial, 1st 5’ lift at Gridline D-5 east around building to Gridline F-5, pending loading dock. Okay to grout progress areas |
| 12/21/2021 |
REINFORCED MASONRY PRE-GROUT |
|
Not ready for Inspection |
NR |