Permit: T21CM06766

Parcel: 13705494G


Addresses:

4800 S LANDING WY

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
08/17/2022 REINFORCED MASONRY PRE-GROUT Approved Approved
02/24/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, top course bond beam, okay to grout all building walls
02/23/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial approval for the 6th and final lift at all building walls. Partial for (4) canopy bases
02/17/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial for the 4th lift on the west, east and north walls (20’) Okay to grout progress areas
02/16/2022 REINFORCED MASONRY PRE-GROUT Cancelled Cancelled by Contractor (rain)
02/15/2022 REINFORCED MASONRY PRE-GROUT Not ready for Inspection NR, rescheduled for next day
02/14/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial for the 3rd lift on the east and north walls (15’) Okay to grout progress areas
02/11/2022 REINFORCED MASONRY PRE-GROUT Cancelled - cancelled by Contractor
02/10/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial for the 3rd lift on the west and north walls (15’) Okay to grout progress areas
02/09/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial for the 2nd lift on the north and east walls (10’) Okay to grout progress areas
02/08/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, second lift North side ok for grout.
02/02/2022 REINFORCED MASONRY PRE-GROUT Partial Approval PARTIAL FRONT BUILDING final lift 26’-6” ok to grout.
01/31/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, 5th lift to 23’-6” ok to grout progress areas.
01/26/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, continued 4th lift for South West elevation ok to grout and proceed.
01/25/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial for 4th lift (28’) from east end column line 1-2.5, all south end, ending at west end column line 3.
01/21/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial for 3rd lift (15’) from east end column line 1-2.5, all south end, ending at west end column line 3
01/19/2022 REINFORCED MASONRY PRE-GROUT Partial Approval - Partial for 2nd lift (10’) from east end column line 1-2.5, all south end, ending at west end column line 3
01/12/2022 REINFORCED MASONRY PRE-GROUT Partial Approval - Partial, 1st 5’ lift at Gridline D-5 east around building to Gridline F-5, pending loading dock. Okay to grout progress areas
12/21/2021 REINFORCED MASONRY PRE-GROUT Not ready for Inspection NR