Permit: T21CM06745

Parcel: 116027260

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T21CM06745

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/30/2021 PLUMBING - FINAL Approved Please add:
T21CM06745
1180 N Chamberlain pl

3090 Ap

Close permit
08/25/2021 PLUMBING - FINAL Partial Approval pa
Water heater installed without a permit. Pressure relief valve installed with flex drain. It must be hard piped without size restriction.
Gas appliances and attached garage require CO detectors be installed.
Flex trap on kitchen sink is not approved for use in a sfr.