Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T21CM06745
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2021 | PLUMBING - FINAL | Approved | Please add: T21CM06745 1180 N Chamberlain pl 3090 Ap Close permit |
|
08/25/2021 | PLUMBING - FINAL | Partial Approval | pa Water heater installed without a permit. Pressure relief valve installed with flex drain. It must be hard piped without size restriction. Gas appliances and attached garage require CO detectors be installed. Flex trap on kitchen sink is not approved for use in a sfr. |