Inspection History Details
Inspection Status: Approved
Inspection History: RESIDENTIAL INTERMEDIATE
Permit Number - T21CM06069
Inspection Description - RESIDENTIAL INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/24/2022 | RESIDENTIAL INTERMEDIATE | Approved | AP | |
03/21/2022 | RESIDENTIAL INTERMEDIATE | Correction Required | CO 1. Seal penetrations in lath 2, flush blocking at garage shear wall 3. Seal around plumbing penetrations in garage wall entering house 4. Block base of water heater stand 5. Support all ABS 90 bends 6. Maintain min 10 feet clearance of fresh air intake to vent 7. Install clean outs at 2nd floor tub, and at 2nd floor shower per plan. 8. B-vent chase open at top & bottom. 9. Excessive hole at B-vent roof sheathing 10. Block registers at 2nd floor 11. Air test copper in garage. Cancel all other inspections. |
|
03/17/2022 | RESIDENTIAL INTERMEDIATE | Cancelled | CA Cancel all other inspections. |