Inspection Status: Passed
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 05/07/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|
| 10/27/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
10/27/23: 2X blocking at existing bearing wall missing, bearing at porch not per plan will need to be revised, headers at windows not per plan will need to be revised, sheathing nail spacing not per plan throughout. |
|
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
11/14/23: exterior has been covered before approval need a letter from building accepting responsibility for structure |