Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T21CM06016

Parcel: 117070800


Addresses:

528 S HERBERT AV


Inspection Status: Passed

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - T21CM06016

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Passed

Date Description Inspector Results Comments
05/07/2024 COT - RSBU - Exterior Clips/Sheathing  Passed
10/27/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 10/27/23: 2X blocking at existing bearing wall missing, bearing at porch not per plan will need to be revised, headers at windows not per plan will need to be revised, sheathing nail spacing not per plan throughout.
COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 11/14/23: exterior has been covered before approval need a letter from building accepting responsibility for structure