Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - T21CM05882
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2022 | COT - RSBU - Exterior Clips/Sheathing | WGALLAGHER | Approved | Entered by VVERA1 - Approved |
12/13/2021 | COT - RSBU - Exterior Clips/Sheathing | WGALLAGHER | Partial Approval | Entered by NGARCIA3 - Partial approval Missing 2 hold downs on rear patio |
12/02/2021 | COT - RSBU - Exterior Clips/Sheathing | TLUNDBERG | Correction Required | Entered by RSALDAT1 - CO 1. Shear panels incorrect at SW corner of 1st floor 2. Double top plate required at bearing point of GLB in great room 3. shear panels loose on 2nd floor 4. Add a support stud under the end of 4-ply girder truss 5. Add a stud at end of 2nd floor shear wall. 6. Sheetrock nailer required at stairway landing 7. Shear wall sole plate nailing incorrect at all 2nd floor shear walls |