Inspection Status: Canceled
Inspection History: COT - RSEL - Electrical Final
Permit Number - T21CM04993
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Canceled
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2022 | COT - RSEL - Electrical Final | Canceled | Inspection Canceled | |
| 12/02/2025 | COT - RSEL - Electrical Final | Re-inspection required | 12/2/25: GFCI required at laundry/water heater room, GFCI not working at second floor bathroom, open chase at mechanical room, disconnect clearance required at mechanical room, pain clean out on exterior, knock out at mechanical room, leak repair behind refrigerator, microwave receptacle must have cover plate and cannot be further than 1/4" behind combustible material, kitchen exhaust not complete, appliances must be installed, receptacle cover plate required at garage, arc-fault required at laundry room breaker, receptacle at roof keeps tripping,supports required at refrigerant lines at roof, check all units for over amped condenser units. Water heater require lock out breakers |