Permit: T21CM04993

Parcel: 117073550


Addresses:

49 W LALO WY


Inspection Status: Canceled

Inspection History: COT - RSPL - Plumbing Final 

Permit Number - T21CM04993

Inspection Description - COT - RSPL - Plumbing Final 

Inspection Status - Canceled

Date Description Inspector Results Comments
11/04/2022 COT - RSPL - Plumbing Final  Canceled Inspection Canceled
12/02/2025 COT - RSPL - Plumbing Final  Re-inspection required 12/2/25: GFCI required at laundry/water heater room, GFCI not working at second floor bathroom, open chase at mechanical room, disconnect clearance required at mechanical room, pain clean out on exterior, knock out at mechanical room, leak repair behind refrigerator, microwave receptacle must have cover plate and cannot be further than 1/4" behind combustible material, kitchen exhaust not complete, appliances must be installed, receptacle cover plate required at garage, arc-fault required at laundry room breaker, receptacle at roof keeps tripping,supports required at refrigerant lines at roof,