Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: RESIDENTIAL INTERMEDIATE
Permit Number - T21CM04687
Inspection Description - RESIDENTIAL INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/15/2022 | RESIDENTIAL INTERMEDIATE | Approved | AP | |
04/01/2022 | RESIDENTIAL INTERMEDIATE | Not ready for Inspection | NR. 1. Block registers 2. Make up electrical boxes 3. Incorrect wire size for stove 4. Duct and registers not per plan 5. VTR kitchen sink per plan Cancel other inspections |