Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/14/2022 |
MECHANICAL - FINAL |
|
Approved |
AP |
| 04/13/2022 |
MECHANICAL - FINAL |
|
Partial Approval |
Partial approval water Heater flue pipe needs to be secured with four screws at every joint, PTR VALVE Is in contact with ground on the exterior of the house, no elbow on drain pan on exterior of house, condenser located to close to house please provide manufacturer specs, line set not sun shielded, catwalk for crawl space in attic is located so truss brace is in conflict with clear crawl space |