Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Passed

Inspection History: COT - RSPL - Rough Soil 

Permit Number - T21CM04477

Inspection Description - COT - RSPL - Rough Soil 

Inspection Status - Passed

Date Description Inspector Results Comments
03/01/2022 COT - RSPL - Rough Soil  TGAUSP Approved Entered by NGARCIA3 - Approved, okay to backfill progress areas
02/22/2022 COT - RSPL - Rough Soil  TLUNDBERG Correction Required Entered by RSALDAT1 - CO 1. Support entire length of pipe with earth 2. Attach trace wire to sewer pipe every 10 foot 3. Bleed off shower stack, it is vapor locked 4. Place enough approved shade material on site to cover all pipe 12” after it passes inspection. NOTE: 2 bearing wall studs were notched well over 25% of its width. Stud shoes may not fit over this large notch.
02/14/2022 COT - RSPL - Rough Soil  TGAUSP Partial Approval Entered by NGARCIA3 - Partial for under slab area, pending site sewer connection