Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: RESIDENTIAL INTERMEDIATE
Permit Number - T21CM04042
Inspection Description - RESIDENTIAL INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2021 | RESIDENTIAL INTERMEDIATE | Approved | . AP | |
12/08/2021 | RESIDENTIAL INTERMEDIATE | Correction Required | CO 1. Vents are dry 2. Exterior outlet box at patio needs a KO 3. Support 4-gang box at both ends 4. Block the base at stair landing 5. Water test tub and shower 6. Block bedroom 4 register 7. Maintain min 10 feet horizontal clearance between vent and fresh air intake 8. Incorrect nail plate in kitchen exterior wall over vent and water lines |