Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T21CM03723

Parcel: 141411580

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - T21CM03723

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Passed

Date Description Inspector Results Comments
05/19/2022 COT - RSBU - Exterior Clips/Sheathing  TLUNDBERG Approved Entered by NGARCIA3 - AP
05/16/2022 COT - RSBU - Exterior Clips/Sheathing  TLUNDBERG Correction Required Entered by VVERA1 - CO 1. Install two posts under girder at each end in front bedroom 2. Remove all shims under trusses, remove all nails connecting truss to walls 3. Garage opening requires 3 king studs each end.