Permit: T21CM03504

Parcel: 133300490

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
08/19/2021 PLUMBING - ROUGH, SOIL Approved -AP
07/26/2021 PLUMBING - ROUGH, SOIL Denied DE 1-Plumbing corrections are completed; however approved building plans show addition four feet from property line, and forms are 12-16 inches from property line.
07/21/2021 PLUMBING - ROUGH, SOIL Denied DE. 1-Provide approved plans. 2-Clean out fittings need to direct waste in the direction of flow. 3-Lav connection to branch drain is vent fitting. 4-Toilet connection to branch drain is vent fitting. 5-Vent connection at toilet is not above the centerline of drain. 6-Connect branch drain to building drain. 7-Provide water test of DWV piping.