Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ELECTRIC - UNDERGROUND
| Date |
Description |
Inspector |
Results |
Comments |
| 03/08/2022 |
ELECTRIC - UNDERGROUND |
|
Approved |
Approved |
| 10/08/2021 |
ELECTRIC - UNDERGROUND |
|
Partial Approval |
Partial, Secondary Conduits from Transformer toe SES location and Communication conduits installed ok to backfill progress areas. |