Inspection Status: Passed

Inspection History: COT - LCBU - Excavation/Rebar/Zoning 

Permit Number - T21CM01203

Inspection Description - COT - LCBU - Excavation/Rebar/Zoning 

Inspection Status - Passed

Date Description Inspector Results Comments
02/04/2022 COT - LCBU - Excavation/Rebar/Zoning  Passed {Activity date: 02/04/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Approved} ; {Activity date: 09/03/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. Column at GL: A/3 CC1. Ok to place concrete in progress area.} ; {Activity date: 09/07/2021; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Partial. Move an epoxy column E6} ; {Activity date: 09/02/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Partial. H/7 CC1; G/7 CC1; F/7 CC1; E/7 CC1; F/6 CC1; G/6 CC1; H/5.5 CC1; G/5 CC3; F/5.5 CC1; E/5 CC2; E/4 CC1; E/3 CC1; E/2 CC2; D/2 CC1; C/2. CC2; C/1 CC3; F/2 CC2; G/2 CC1; G/3 CC1; G/4 CC1} ; {Activity date: 09/01/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VVERA1 - 01005. Partial. Concrete columns at GL: C/4 CC1; C/5 CC2; C/5.4 CC3; C/6 CC1; B/5.5 CC1; B/6 CC1; B/2 CC3; A/1 CC3. Ok to place concrete in progress areas.} ; {Activity date: 08/31/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Partial. Column footings at GL: B5 F5 CC2; B4 F5 CC1. Pier cap #1 at GL: A/3.5 - 5.6. Ok to place concrete in progress areas.
} ; {Activity date: 08/30/2021; Status: Not ready for Inspection; Inspector: ESTEVENES; Comment: Entered by VVERA1 - Not ready.} ; {Activity date: 08/26/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VVERA1 - Partial. Column footings at GL: F-6 footings 2/D; 2/E; 2F; F-5 footing 2/G. F-5 footings at GL: 6/E; 6F; 6G; 7/E; 7/F. Shear wall #1 on GL: 8/H-J.

Ok to place concrete in progress areas.} ; {Activity date: 08/25/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. Column footings on GL: B/5 F5 CC2; E/4 F7 CC1; F/4 F7 CC1; F/5 F5 CC2/; G/5 F5 CC2; G/4 F7 CC1; H/7 F5 CC1; G/7 F5 CC1. Columns on GL: 8/D; 8/E; 8/F; 8/G; J/7; 5.6/E; 5.6/D; D/6; D/7. Ok to place concrete in progress areas.} ; {Activity date: 08/24/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VVERA1 - Partial. Concrete column footings at GL: D/1 F2 CC3; D/5 F5 CC2; C/5. F5 CC2; C/4 F7 CC1; B/4 F8 CC1; A/3 F3 CC3; A/2. F2 CC3; B/2 F4 CC3; C/2 F4 CC3. Footings on GL: 2/A-C (F10-F11); A/2-3.5 (F11); 1/C-D.5. (F11). Ok to place concrete in progress areas.} ; {Activity date: 08/19/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. Concrete columns at GL: E/5.5; F/5.5; G/5.5; H/5.5.} ; {Activity date: 07/02/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. Grade beams in loading dock area. Ok to place concrete in progress areas.} ; {Activity date: 08/23/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VVERA1 - Partial. Footings at GL: 1/H-J; Shear wall #2 at GL: 1/E-F; Column footing at GL: A/8 CC1, F4 and F10. Ok to place concrete in progress areas.} ; {Activity date: 08/23/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/20/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/20/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/20/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/18/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VVERA1 - Partial. Column footings at GL: B/5.5 (F-3) at 28”; C/6 (F-6) at 38”; C/7 (F-7) at 38”. Ok to place concrete in progress areas.

} ; {Activity date: 08/17/2021; Status: Not ready for Inspection; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Not ready. Contractor cancelled, rained out.

} ; {Activity date: 08/16/2021; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VVERA1 - pa
SW #5 - GL J - 5 to 6

} ; {Activity date: 08/13/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/13/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/13/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/12/2021; Status: Not ready for Inspection; Inspector: JBURGE; Comment: Entered by VVERA1 - 01005. Not ready. Site too wet to excavate footings. Will reschedule for 16 August.} ; {Activity date: 08/11/2021; Status: Not ready for Inspection; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Not ready. Contractor cancelled due to wet site.} ; {Activity date: 08/10/2021; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - Columns G-5.4, G-5.6. F-5.4, F-5.6, E-5.4, E-5.6. G-1, H-1.} ; {Activity date: 08/09/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/09/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/09/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/09/2021; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - Partial. Sheer wall SW5. Exterior footings and foundations from gridlines F1 to E1. Columns on Gridline H, line 5, 5.5, 6.} ; {Activity date: 08/06/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. Columns on GL: H/2 CC2; H/3 CC1; H/4. CC1; H/5. CC2; H/6 CC1; H/7 CC1; J/4 CC2; J/5 CC2; J/6 CC2. Footing on GL: 1/G-J. Ok to place concrete in progress areas.} ; {Activity date: 08/05/2021; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - Gridlines J3 to J4.
Gridlines 3.5 G to J
Gridlines 5.5. E to H.

} ; {Activity date: 08/04/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/04/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/04/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 08/04/2021; Status: Not ready for Inspection; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Not ready; Foreman cancelled. Will reschedule for 5 August.} ; {Activity date: 08/03/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. Column footings on GL: H/4 (CC1-F7); H/5 (CC2-F5); Shear wall 35 footing at GL:J/5-6. Ok to p;ace concrete in progress areas.} ; {Activity date: 08/02/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. Column footings at GL: 1/G (CC2/F5); 3/G (CC1/F7); 4/G (CC1/F7); 5/G (CC2/F5); 4/H (CC1/F7). Ok to place concrete in progress areas.} ; {Activity date: 07/30/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. Column footings at GL: J/.5-2.75 (CC-2 columns); footing at GL: 1/H.75. Ok to place concrete in progress areas.

} ; {Activity date: 07/30/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 07/30/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 07/30/2021; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 07/29/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Partial. F-4 footing at GL: J/1. Ok to place concrete in progress areas.} ; {Activity date: 07/28/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VLEON1 - Partial. Southwest corner of site, columns at GL: J/1-2.5; CC1 and CC2 Columns. 3” of co