Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T21CM01129
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2021 | PLUMBING - FINAL | Approved | 3-COMPARTMENT SINK NOT USED FOR FOOD PREP, INDEPENDENT INDIRECT DRAINS FROM EACH COMPARTMENT NOT REQUIRED (SECTION 802.1.1, IPC 2018) | |
08/13/2021 | PLUMBING - FINAL | Denied | de 3 compartment sinks need separate drains and a 2” air gap above the flood rim of the floor sink, to prevent cross contamination. |
|
07/08/2021 | PLUMBING - FINAL | Not ready for Inspection | nr Called in because 3040 was not on permit. |