Inspection Status: Not Ready

Inspection History: COT - HCEL - Electrical Underground 

Date Description Inspector Results Comments
10/26/2022 COT - HCEL - Electrical Underground  Not Ready
03/02/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by VVERA1 - Partial, site lighting conduits ok to backfill progress areas.
03/01/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by NGARCIA3 - Partial, underground conduits installed for site lighting ok to backfill progress areas.
02/28/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by VVERA1 - Partial, underground conduits installed for site lighting ok to backfill progress areas.
02/17/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by VVERA1 - Partial, secondary conduits installed
02/08/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by NGARCIA3 - Partial, under foundation conduits and boxes installed West side.
01/31/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by NGARCIA3 - Partial, Raceways under foundation complete ok to backfill.
01/28/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by VVERA1 - Partial, no inspection required today, see previous notes.
01/25/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by RSALDAT1 - Partial, UNDERGROUND CONDUIT sweeps into future Electrical room for under slab raceways installed and ok to backfill progress.
01/24/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by RSALDAT1 - Partial, conduits under slab From continued SES feed to Electrical Distribution panel north of elevator shaft & branch raceways west all ok to backfill progress areas.
01/18/2022 COT - HCEL - Electrical Underground  TGAUSP Partial Approval Entered by VVERA1 - Partial, secondary conduits from SES location, stubbing out within 5’ of transformer, also 2” conduit to vehicle charging location, okay to backfill progress areas
01/13/2022 COT - HCEL - Electrical Underground  DMUNIZ Partial Approval Entered by VVERA1 - PARTIAL, inspection For Underground Raceway from ELECTRICAL room to Communication room ok to backfill progress.
03/01/2023 COT - HCEL - Electrical Underground  Passed