Inspection Status: Not Ready
Inspection History: COT - HCBU - Exterior Clips/Sheathing
| Date |
Description |
Inspector |
Results |
Comments |
| 10/26/2022 |
COT - HCBU - Exterior Clips/Sheathing |
|
Not Ready |
|
| 06/03/2022 |
COT - HCBU - Exterior Clips/Sheathing |
DMUNIZ |
Partial Approval |
Entered by NGARCIA3 - Partial, 4th floor exterior clips ok to proceed. |
| 05/27/2022 |
COT - HCBU - Exterior Clips/Sheathing |
DMUNIZ |
Partial Approval |
Entered by NGARCIA3 - PARTIAL, NORTH WEST WING 3RD & 4th floor clips installed & ok to proceed. |
| 05/19/2022 |
COT - HCBU - Exterior Clips/Sheathing |
DMUNIZ |
Partial Approval |
Entered by NGARCIA3 - Partial, exterior clips inspected to 3rd floor ok to continue sheathing. |
| 05/06/2022 |
COT - HCBU - Exterior Clips/Sheathing |
DMUNIZ |
Partial Approval |
Entered by NGARCIA3 - Partial, 1sr & 2nd floor shear walls and straps complete installed ok to proceed. |
| 04/29/2022 |
COT - HCBU - Exterior Clips/Sheathing |
DMUNIZ |
Partial Approval |
Entered by VVERA1 - Partial, 1st & 2nd floor shear walls and h2.5 clips installed. Note: strap continuous double top plates where cut.
|
| 04/26/2022 |
COT - HCBU - Exterior Clips/Sheathing |
DMUNIZ |
Not ready for Inspection |
Entered by NGARCIA3 - Not Ready, Install all h2.5 hardware and shear wall nailing prior to Inspection. |
| 03/16/2022 |
COT - HCBU - Exterior Clips/Sheathing |
TGAUSP |
Partial Approval |
Entered by VVERA1 - Partial shear panel between mechanical rm and room 131 |
| 08/18/2022 |
COT - HCBU - Exterior Clips/Sheathing |
WGALLAGHER |
Approved |
Entered by NGARCIA3 - Approved |
| 03/01/2023 |
COT - HCBU - Exterior Clips/Sheathing |
|
Passed |
|