Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T20RW03706

Parcel: 141022160

Inspection Status: Approved

Inspection History: TDOT-EXCAV GENERAL INSPECTION

Permit Number - T20RW03706

Inspection Description - TDOT-EXCAV GENERAL INSPECTION

Inspection Status - Approved

Date Description Inspector Results Comments
07/09/2020 TDOT-EXCAV GENERAL INSPECTION Approved Performed final inspection. Observed no cracks in sidewalk, or driveway. Slope percentage was under 2%. Work completed.
07/02/2020 TDOT-EXCAV GENERAL INSPECTION Continued Lot 2020 was inspected. All forms were under 2%, subgrade was dense and firm. Sidewalk depth 4", driveway depth 6". Will pour next week.