Permit: T20RW01817

Parcel: Unknown

Inspection Status: Passed

Inspection History: TRSP - ROW - Recurring

Permit Number - T20RW01817

Inspection Description - TRSP - ROW - Recurring

Inspection Status - Passed

Date Description Inspector Results Comments
04/08/2021 TRSP - ROW - Recurring Passed TDOT-EXCAV GENERAL INSPECTION - Project completed. All equipment associated with the tower installed in landscaped shoulder. A retaining wall installed behind the tower due to the slope of the landscape. All landscape gravel restored. Power run to slab mount a transformer Installed. Two potholes repaired in street at the power run. Landscape around transformer restored. One sidewalk panel replaced along the power run. No light bar installed on pole. Site cleaned up. Permit closed.
03/18/2021 TRSP - ROW - Recurring Passed TDOT-EXCAV GENERAL INSPECTION - All equipment installed. Retaining wall around pole installed. Graveled shoulder has been restored to original condition. Roadway not affected . One sidewalk panel has been replaced. Project completed. Meter installed. Permit closed.
02/10/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Pole installed. All boxes installed. Landscaping in the process of being restored. Retainer wall around Pole due to sloping shoulder completed. Crews presently working on cable box.
02/03/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Pole and foundation installed. Formwork set for installing retainer wall around Pole location due to the steep slope of the landscape shoulder.
04/08/2021 TRSP - ROW - Recurring Passed TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site.
01/13/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Not Ready for Inspection
03/18/2021 TRSP - ROW - Recurring Passed TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site.
02/10/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Continued
08/28/2020 TRSP - ROW - Recurring Passed TDOT-EXCAV GENERAL INSPECTION - No bluestake. No sign of work.
02/03/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Notify contractors of the barricade set up around the trench to the pad mounted transformer have fallen into the ditch and need to be reinstalled immediately. Also, sidewalk close signs at this location need to be installed.
06/01/2020 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - No blue stake. No sign of work.
01/13/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Not Ready for Inspection. Precon at site. All work behind existing sidewalk in landscaped gravel. No change to plans.
05/13/2020 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Site layed out. No sign of work.