Inspection Status: Re-inspection required
Inspection History: TRSP - ROW - Recurring
Permit Number - T20RW01816
Inspection Description - TRSP - ROW - Recurring
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/25/2021 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - All components of the cell tower have been installed. No meter installed in meter pedestal. All work performed in graveled dirt shoulder. Graveled landscape and shoulder has been cleaned up. No sidewalks in area. Roadway not affected. Plans call for a light arm installed on Pole but because no city power as of yet to site arm will not be installed. There is a hole excavated near the power pole exposing conduit for Phone. | |
02/10/2021 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - Pole footing poured. Some boxes set. All work in dirt shoulder. Roadway not affected. Power conduit run to and up pole. No sidewalk at power pole location. | |
04/06/2021 | TRSP - ROW - Recurring | Passed | TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site. | |
01/05/2021 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - Not Ready for Inspection | |
03/25/2021 | TRSP - ROW - Recurring | Passed | TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site. | |
03/25/2021 | TRSP - ROW - Recurring | Passed | TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site. | |
10/28/2020 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - Not Ready for Inspection. No blue steak. No layup. No sign of work. Expired permit. Closed permit. | |
02/10/2021 | TRSP - ROW - Recurring | Re-inspection required | TDOT-Routine Barricade Inspect - Continued. | |
10/23/2020 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - Not Ready for Inspection. No blue steak. No sign of work. No layout for new location. | |
01/27/2021 | TRSP - ROW - Recurring | Re-inspection required | TDOT-Routine Barricade Inspect - Not Ready for Inspection. Precon held today at jobsite. No sidewalk in area - gravel shoulder. Electric power is across the street. Work should start next week. | |
09/30/2020 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - No sign of work, No blue staking. | |
01/05/2021 | TRSP - ROW - Recurring | Re-inspection required | TDOT-Routine Barricade Inspect - Not Ready for Inspection | |
07/06/2020 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - No sign of work. | |
06/10/2020 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - No sign of work. | |
10/28/2020 | TRSP - ROW - Recurring | Re-inspection required | TDOT-Routine Barricade Inspect - Not Ready for Inspection | |
04/06/2021 | TRSP - ROW - Recurring | Passed | TDOT-EXCAV GENERAL INSPECTION - Project completed. All components of tower site installed. All work performed in graveled shoulder. No sidewalks in area. Curb and roadway not affected. Meter not installed in pedestal. Site raked and cleaned up. Power run to Pole installed under roadway. There is a separate permit to work near the seawall that the power run went to which is not part of this project. | |
03/25/2021 | TRSP - ROW - Recurring | Passed | TDOT-EXCAV GENERAL INSPECTION - Notified by the city electrical inspector that the hole near the power pole that appears to be for a phone line was excavated after the contractor completed this tower site and work being performed by the phone company. | |
05/13/2020 | TRSP - ROW - Recurring | Re-inspection required | TDOT-EXCAV GENERAL INSPECTION - No sign of work. | |
10/23/2020 | TRSP - ROW - Recurring | Re-inspection required | TDOT-Routine Barricade Inspect - Not Ready for Inspection |