Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T20OT00447

Parcel: 10408009E


Addresses:

4631 N ORACLE RD


Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Permit Number - T20OT00447

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
02/03/2021 COT - ENGR - Signage Final Hthrall1 Approved Entered by HTHRALL1 -
02/01/2021 COT - ENGR - Signage Final Hthrall1 Continued Entered by HTHRALL1 - revised engineering submitted 2/1/21
01/07/2021 COT - ENGR - Signage Final Hthrall1 Continued Entered by HTHRALL1 - Singular sign design option approved under T20SA00381 on 1/7/21 with appeal period of 1/21/21. MSP20-015.
07/10/2020 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - RE: sign alteration review - modify existing pole sign At: 4619 / 4631 N Oracle Rd Permit: T20OT00447 Date: 7/10/2020 Reviewer: H. Thrall Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Codes (NEC), Tucson Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1) Proposal is to modify existing pole sign to increase height and sign area to add one additional LED cabinet atop the sign structure. 2) Sign Standards UDC 7A: A) **SDRC review required to increase pole sign to 14' tall** (UDC 7A. 10. 2. C max height allowed is 12' feet height) B) **SDRC review required to increase sign area to 95.6 square feet** - UDC 7A.10.2.c. exceed 72 sq.ft. max pole sign C) Setback remains adquate for a pole sign at 32' (min 30') D) SDRC = Sign Design Review Committee evaluation required to exceed code allowances for a pole sign. Contractor has been provided applications. E) Provide inventory of freestanding signs for site (auto mall dr frontage) - show on aerial. _____ The following comments are provided for review, for consideration of process, should the SDRC grant a pole sign height and sign area increase _______ 3) International Building Code (IBC): A) existing footer is 7x 3 - engineered plans required to show sufficient footer B) provide original sign permit to determine existing pole is sufficient with the engineering, for the new increase in sign area, including existing surface. B) plans indicate field welds - special inspection required 4) National Electrical code (NEC) 600: / OLC: A) indicate if new cabinet will tie into existing circuit / timer B) indicate if new cabinet will have separate shut off switch? Send revisions / SDRC applications to Heather.Thrall@tucsonaz.gov