Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - ENGR - Signage Final
Permit Number - T20OT00367
Inspection Description - COT - ENGR - Signage Final
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | COT - ENGR - Signage Final | Not Ready | ||
02/22/2021 | COT - ENGR - Signage Final | Hthrall1 | Approved | Entered by HTHRALL1 - |
02/18/2021 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - Resubmitted site plan received 2/17/21 for altered monument sign location. Under review. |
07/14/2020 | COT - ENGR - Signage Final | Hthrall | Approved | Entered by HTHRALL1 - 7/9/2020 submittal received / approved on 7/14/2020. HT |
07/09/2020 | COT - ENGR - Signage Final | HThrall | Partial Approval | Entered by HTHRALL1 - RE: sign permit review For: wall signs / monument sign AT: 6555 S Bay Colony Drive / Home 2 Suites by Hilton Permit: T20OT00367 Reviewer: H. Thrall Date: 07/09/2020 Codes: Unified Development Code (UDC) Sign Standards 7A, National Electrical Code (NEC) 600, Outdoor Lighting Code (OLC) of Tucson - Pima County, and International Building Code (IBC) 2018. ** As staff has discussed with contractor, please note the proposed signs are within sign type and sign area allowances under the Industrial zoning of the site. The following review comments are to be addressed for inspections / permit record, to show code compliance with specific mounting, electrical and Sign Standards criteria. ** 1) UDC 7A.10.2. Sign Standards: a) List the total sign area of each sign, including monument sign, on the diagram for that respective sign (i.e. 14 x 6.83 = 95.62 square feet sign area) 2) UDC. 7A. - Sign standards - monument sign a) List the note "maximum sign height is 10' - taken from the average grade point within a 5' radius of the sign. Send revisions to Heather.Thrall@tucsonaz.gov |
05/13/2020 | COT - ENGR - Signage Final | HThrall | Continued | Entered by HTHRALL1 - RE: sign permit review For: wall signs / monument sign AT: 6555 S Bay Colony Drive / Home 2 Suites by Hilton Permit: T20OT00367 Reviewer: H. Thrall Date: 5/13/2020 Codes: Unified Development Code (UDC) Sign Standards 7A, National Electrical Code (NEC) 600, Outdoor Lighting Code (OLC) of Tucson - Pima County, and International Building Code (IBC) 2018. ** As staff has discussed with contractor, please note the proposed signs are within sign type and sign area allowances under the Industrial zoning of the site. The following review comments are to be addressed for inspections / permit record, to show code compliance with specific mounting, electrical and Sign Standards criteria. ** 1) Label each sign on the plans to correspond to the line item on the permit application (sign, A, B, C and D). 2) UDC 7A.10.2. Sign Standards: A) Note sign dimensions on diagrams in decimal feet, rather than inches. B) Ensure application also matches the sign area diagrams. C) List the total sign area of each sign on the diagram. D) Provide approximate heights off the ground for each sign E) On site plan, note "building frontage off Bay Colony, 247 feet" F) On site plan, note "building frontage off Valencia is 60 feet" G) On site plan, type in the property line frontage off Valencia (too small to read) 3) Mounting of wall signs / IBC 2018: A) Provide specific size of lag bolts, and typical number 4) Electric for wall signs: A) List amps and total circuit for each sign (acknowledge volts) 5) Outdoor Lighting Code: A) Provide note "maximum color temperature is 4400k" (all internally illuminated signs shall have this note) B) Provide a timer for all signs (OLC ch.4) and list location 6) Regarding monument sign: A) Provide sign dimensions in decimal feet B) Provide total sign area on the elevation view C) Note amps D) Note location of sign circuit and lock out for inspections E) Provide clarification - sign within retention or detention basin? (all electrical must be at top of cabinet, water tight cabinet system - further review comments may be forthcoming) F) Check that footer is sufficient, given placement proposal G) Provide note "maximum light brightness is 4400k" for internal illuminated sign. H) Provide and indicate timer location Send revisions to Heather.Thrall@tucsonaz.gov |