Permit: T20OT00230

Parcel: 137055690


Addresses:

4745 S LANDING WY


Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Permit Number - T20OT00230

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
03/01/2021 COT - ENGR - Signage Final bwiese1 Not ready for Inspection Entered by BWIESE1 - more time needed, construction stopped for covid
04/08/2020 COT - ENGR - Signage Final Hthrall1 Approved Entered by HTHRALL1 - Revised plans and neon diagram provided 4/8/2020. Approved.
03/27/2020 COT - ENGR - Signage Final Hthrall Partial Approval Entered by HTHRALL1 - ** REVISED ENTRY** SIGN AREA, AS SHOWN ON PLANS / APPLICATION - IS WITHIN ALLOWANCE, APOLOGIES TO CONTRACTOR FOR STAFF ERROR. THE FOLLOWING ARE REVISED REVIEW COMMENTS 3/27/20 RE: sign permit review For: Ojos Locos Cantina At: 4745 S Landing Way - at the Spectrum Permit: T20OT00230 Reviewers: H. Thrall / D. Santa Cruz Date: 3/23/2020 1) UDC 7A.10.2.B. Sign area maximum ratio is 4 to 1, given 250' proximity to freeway. 122 x 4 = 488 allowance, plans accurate. A) Acknowledge landlord approval letter sent allows the proposed signs (neon and paint) 2) Outdoor Lighting Code: The maximum light brightness for an internally illuminated sign is 4400K. Revise plan to show, check that the neon to be used is within this criteria. B) (Clear cover allowed specifically for neon per policy and 2017 Building Official's determination.) C) Provide timer and note location. D) specify the sign shall abide by city curfew of midnight or at business closure, if later. 3) Welding noted on the plan - specify if field or shop. Field welds require engineered plans and special inspection. 4) Enlarge neon detail please, and darken - came out pixelated. Needs clear detail for review of electrical details with bushings and electrodes. B) note where the circuitry is located within the building for these signs - for inspections Please send revision to Heather.Thrall@tucsonaz.gov
03/23/2020 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - RE: sign permit review For: Ojos Locos Cantina At: 4745 S Landing Way - at the Spectrum Permit: T20OT00230 Reviewers: H. Thrall / D. Santa Cruz Date: 3/23/2020 1) UDC 7A.10.2.B. Sign area maximum ratio is 4 to 1, given 250' proximity to freeway. A) Sign area is calculated 122 (includes patios) x 4 on plans -ok to include the handicapped parking, as this is reserved specifically for this building (much like a drive thru would be for other uses). B) sign area currently shown 56 square feet over, however, more negative space is counted within the boxed areas relating to the wording "sports" and "cantina" and their shapes. Per UDC 7A.6.1.A, box these two words separately from the other wording to exclude the negative space. C) Acknowledge landlord approval document allows the proposed signs (neon and paint) D) Check sign area for C and do the same with boxing the positive space, as so much unused space is included with the wording/shape of the sign. E) signs 12 square feet and less are not included in the sign area, as they are meant to be seen by on site users, just keep on plan and app - know reviewer deducted one already. 2) Outdoor Lighting Code: The maximum light brightness for an internally illuminated sign is 4400K. Revise plan to show, check that the neon to be used is within this criteria. B) (Clear cover allowed specifically for neon per policy and 2017 Building Official's determination.) C) Provide timer and note location. D) specify the sign shall abide by city curfew of midnight or at business closure, if later. 3) Welding noted on the plan - specify if field or shop. Field welds require engineered plans and special inspection. 4) Enlarge neon detail please, and darken - came out pixelated. Needs clear detail for review of electrical details with bushings and electrodes. B) note where the circuitry is located within the building for these signs - for inspections Please send revision to Heather.Thrall@tucsonaz.gov
06/23/2021 COT - ENGR - Signage Final MHERNANDEZ Continued Entered by VLEON1 - CN RESCHEDULE FOR TOMORROW