Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T20OT00058

Parcel: 123020860


Addresses:

2500 E GRANT RD 182


Inspection Status: Continued

Inspection History: SIGN SITE REVIEW

Permit Number - T20OT00058

Inspection Description - SIGN SITE REVIEW

Inspection Status - Continued

Date Description Inspector Results Comments
02/03/2020 SIGN SITE REVIEW Continued Received revised plans 2/3/2020
02/03/2020 SIGN SITE REVIEW Approved
01/16/2020 SIGN SITE REVIEW Continued RE: sign permit review
For: canopy / wall signs
AT: 2500 E Grant #182 / SNOOZE
Permit: T20OT00058
Reviewer: H. Thrall
Date: 1/16/2020

Codes: International Building Code 2018 (IBC), Sign Standards (UDC 7A), National Electric Code, Outdoor Lighting Code (Ch 4 & 5)


1) Mounting clarifications, please:
A) ID material of square tubing (assume a metal)
B) welds noted, identify if field or shop - field welds require engineering plans and special inspection
C) ID letters attached to square tubing
D) label building canopy on all diagrams
E) how are wall signs mounted?
F) ID materials used to make wall sign lettering
G) ID vertical parapet surface behind lettering to ensure these remain canopy signs and not roof signs (prohibited) - on all sheets

2) Clarify on elevation or site sheet the dimension of each street front, as sign area is taken off streets.

3) NEC
A) appears from description both halo and internal lighting used, note where/which.
B) call out shut off switch for each sign
C) ID location of circuit breaker for inspections and lock outs as needed

4) Send revised plans to Heather.Thrall@tucsonaz.gov