Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/07/2020 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL OUT BY TFD: EMERGENCY CAL OUT BY TFD: THERE IS FIRE DAMAGE TO THE ROOF MEMBERS OF THE BEDROOM AREA, ESTIMATED AREA IS 8 FEET BY 8 FEET OF DECKING BOARDS, TWO 2 X 4 RAFTER HAVE HEAT DAMAGE ALONG WITH CROSS MEMBERS. THE FIRE ZONE FOR THE ROOF MEMBERS HAVE DEEP CRACKING WITH CHARRING. THERE IS 3 ROOF PENETRATIONS. THERE ARE TWO 2 X 4 CEILING JOIST WHICH ARE BROKEN, THE SHEETROCK IS DAMAGED TO THE BEDROOM ROOM DIMENSION ESTIMATE IS 12 X 12. ELECTRICAL: THERE ARE 5 RUNS OF BX ARMOR CABLE WHICH MEET AT THE CEILING 3 INCH FAN BOX. THESE CABLE HAVE HEAT DAMAGE. TEP DID DISCONNECT POWER. PLUMBING: N/A MECHANICAL: (1) 6 BY 12 METAL DUCT WORK TO ROOM IS DAMAGED, SMOKE IS MILD. REMARKS: PERMIT REQUIRED FOR REPAIRS, OWNERS TO SECURE THE HOME. THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY. |