Case: T20DV07286

Parcel: 136371460


Addresses:

3960 S EVERGREEN AV

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
10/06/2021 INSP - FOLLOW UP CODE ENFORCE Approved The property has been sold and has a new owner. Have talk to the new owner and will be sending a N.O.V. to the new owner. The owner has been fined for not showing up and the case closed. At this time the case will be closed. Violation Abated, Close Case. RV.
08/05/2021 INSP - FOLLOW UP CODE ENFORCE Approved TPD CALL OUT, BROKEN WINDOWS, BOARDING REMOVED. TRANSIENT ACTIVITY
07/28/2021 INSP - FOLLOW UP CODE ENFORCE Approved Met with the owner on site and the drywall was taped on with masking tape and was already falling off due to the heat. Told the owner that the drywall needs to be placed correctly and should call someone that knows what they are doing. The flooring has pieces glued on to the filler that was added to fill the void in the floor. The pieces that were added were pulling off. The permit for the AC has not been issued for the new install. The boards have been pulled off and not sure who told the owner that the plywood can be pulled off. Will be checking on if the wall is bearing that was removed in the living room. RV.
07/08/2021 INSP - FOLLOW UP CODE ENFORCE Approved Met with the owner on site and checked some of the work done. The water heater is leaking water where the plug blew off, the interior ceiling in the living room needs to have the openings patched, the flooring in the same area needs to be completed on the patch. The owner is asking on getting the electrical back on and went over that he needs the re-connect permit to have the electrical inspected and once approved the clearance will be given and the electrical will be turned back on. Did leave the plywood off the rear sliding glass door and did let him know that if called back due to people in the house that the boards will go back up and a contractor will be required to complete the work. Did check on the permit for the AC and the contractor has just applied online and waiting for the results. The owner will call back for the permit and when completed on the other items needed to be done. RV.
07/07/2021 INSP - FOLLOW UP CODE ENFORCE Approved Did check the exterior of the property and the property is cleaned, the plumbing has been capped where tied to the clean-out, and not able to enter the property. Will check tomorrow. RV.
05/28/2021 INSP - FOLLOW UP CODE ENFORCE Approved Check the site for the work with out permits and the wall in the living room has been removed making a room but still has the closet and the wall being blocked off to the kitchen area. The walls making the closet will need to be removed to be back to the orginal layout. Still lacking the smoke detectors in the bedrooms, the wall on the rear porch are still up and will need to be removed and back to a porch. Does have 4 coarse of block at the west side that will need to be removed and the water lines for the hot and cold will need to be removed to the water heater. The sewer drainage line that is connected to the clean-out will need to be removed and capped at the clean-out. The owner is stating about making that area into a kitchen and will need to have the permit approved on what work is going to be done. If that work is going to be done than the citation will stay in place. The owner will remove the walls and the block and will call to check when completed. RV.
03/25/2021 INSP - FOLLOW UP CODE ENFORCE Approved Went to the site due to keep getting calls on the property on work being done and still don't have a permit. Did meet with the owner and he was leaving and gave permission to enter the house to take pictures for the citation. Did ask one of the people staying in the house if he wanted to walk with me and he said no that I had permission to enter. Did take pictures of the room being enclosed at the rear porch and the interior of the house where a room was added to the kitchen area and the living room has been changed into a room. Did not find any smoke detectors anywhere in the rooms or the hallway. Will do the citation. RV.
01/14/2021 INSP - FOLLOW UP CODE ENFORCE Approved Received E-mail on gas leaking from the gas meter. Arrived and not able to smell gas in the area. Did talk to some neighbors and they were not smelling gas at this time. Did call Southwest Gas due to the pipe to the resident is leaning over and can see where tire marks are on the pipe. Southwest Gas sent a tech. was sent and the area was checked