Case: T20DV05474

Parcel: 10706063B


Addresses:

1171 W MIRACLE MILE

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/08/2020 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, SPACE #37 WITH INSPECTOR BERMUDEZ, MET WITH TFD CAPTAIN WHO STATED THAT A LITHIUM BATTERY FROM A KIDS CAR EXPLODED AND STATED THE LAUNDRY SHED ON THE EXTERIOR OF THE TRAILER ON FIRE. TFD THEN EXITED THE SCENE. THE NORTH AND WEST WALLS OF THE ILLEGAL LAUNDRY SHED WERE VERY FIRE DAMAGED. THE SHED SAT IN FRONT OF THE HOTWATER HEATER ROOM WHERE THE OWNER TAPPED INTO WATER FOR THE WASHER AND THERE WAS A JUNCTION BOX FOR THE WASHER AND DRYER, NO COVER PLATE. WIRING EXPOSED. THERE MAY BE POSSIBLE DAMAGE TO THE PLUMBING OR HOTWATER HEATER AS THE FIRE MELTED THE SIDING AROUND THE ROOM AND PLUMBING EXPOSED TO HIGH HEAT. THE FIRE MELTED THE SIDE OF THE TRAILERS METAL AND THERE WAS FIRE DAMAGE TO SEVERAL OF THE TRAILERS STUDS THAT MAY REQUIRE REPLACEMENT AS IT IS THE EXTERIOR BEARING WALL FOR THE LIGHT WEIGHT ROOF.THERE WAS ALSO A WINDOW MISSING FROM THE BEDROOM BUT WAS COVERED BY PLASTIC. I ASKED TO SEE THE ELECTRICAL SUB PANEL AND WHEN ALLOWED INSIDE I FOUND THE OWNER HAD COMPLETED ALOT OF WORK ON THE INSIDE OF THE TRAILER AND STILL NOT COMPLETED 100 % BUT LIVING IN THE TRAILER. FOUND ALL NEW DRYWALL THRU OUT THE TRAILER. FOUND THER EAR BEDROOM DOOR HAD NOT BEEN INSTALLED AND FELL AGAINST THE WALL WHERE THE ELECTRICAL SERVICE SUB PANEL WAS INSTALLED APPROXIMENTLY 36 INCHESTO THE TOP OF THE PANEL FROM THE FLOOR. POWERE WAS TURNED OFF AT THE MAIN SERVICE THAT WAS LOCATED ON THE TELEPHONE POLE BEHIND THE UNIT. THE OWNER HAD CONTACTED A ELECTRICIAN WHO WAS NOT A CONTRACTOR BUT SHOWED ME HIS JOURNEYMANS CARD. HE CHECKED THE BREAKERS AND WIRING FOR CONTINUITY AND CHECKED THE POWER AT THE POLE. HE REMOVED 3 BAD BREAKERS FROM THE SERVICE PANEL BUT STATED HE COULD ISOLATE AND LEAVE THE REFRIGERATOR BREAKER AND THE COOLER ON. THE OWNER STATED HIS WIFE AND KIDS WOULD BE STAYING WITH HIS MOTHER. HE ASKED MANY QUESTIONS ABOUT WHAT HE COULD BE DOING TO MINIMIZE COST, I EXPLAINED HE WOULD NEED TO START CLEANING UP THE EXTERIOR, REMOVE THE ILLEGAL LAUNDRY SHED AND REMOVE METAL FROM THE SIDE OF THE TRAILER. I EXPLAINED THAT A NOV WOULD BE ISSUED AND PERMITS REQUIRED. AND THAT WORK SHOULD BE COMPLETED BY A GENERAL CONTRACTOR. HE STATED HE ALREADY BUT ALOT OF MONEY INTO THE TRAILER AND WOULD NEED TO EVALUATE WHETHER FIXING THE TRAILER WOULD BE A ISSUE. A NOV WAS ISSUED FOR PERMITS REQUIRED FOR THE ILLEGAL SHED, ELECTRICAL, PLUMBING, AND STRUCTURAL WALL OF THE TRAILER. A SECOND NOV WAS ISSUED FOR A EMERGENCY VACATE AND THE TRAILER WAS POSTED WITH A DO NOT ENTER PLACARD. OWNER WAS TOLD HE COULD ONLY ENTER T GET NCESSITIES, CLOTHING AND MEDICATIONS. HIS MOTHER AND FATHER ARRIVED TO HELP WITH THE KIDS AND BELONGINGS. SECURING WAS NOT REQUIRED AND INDEMNIFICATION WORK WAS ISSUED DUE TO OWNER OPTING TO SECURE. OWNER WAS ALSO INFORMED THAT HE MAY NEED TO CONTACT STATE OF ARIZONA TO INSPECT THE TRAILER AS WELL. IT SOUNDS LIKE THE TRAILER WAS A LEASE TO OWN. COMPLIANCE / CLOSE CASE.
08/08/2020 INSP - INITIAL CODE ENFORCMENT Approved ON SITE; WITH SENIOR INSPECTOR GGOODMAN FOR TRAINING.