Case: T20DV05004

Parcel: 111061690


Addresses:

2808 N DODGE BL

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
07/19/2021 INSP - FOLLOW UP CODE ENFORCE Approved PROPERTY HAS BEEN CLEANED UP, ELECTRICAL ISSUES HAVE ADDRESSED WITH PERMITS T20CM09059 T20CM07636 FOR A/C UNITS AND ELECT RECONNECT. WILL CLOSE CASE AT THIS TIME.
10/16/2020 INSP - FOLLOW UP CODE ENFORCE Approved ON SITE; 80 PERCENT DONE, 20 PERCENT LEFT TO REMOVE FROM THE REAR YARD ONLY. WILL CLOSE CLOSE THE PORTION OF THE CASE FOR THE REFUSE AND OUTDOOR STORAGE. WILL FOLLOW UP TO THE DWELLING VIOLATIONS AS PREVIOUSLY SCHEDULED ON 11/20/20.
09/08/2020 INSP - FOLLOW UP CODE ENFORCE Approved ON SITE; WITH OWNER, OCCUPANTS FOUND INSIDE DWELLING, SPOKE WITH MALE OCCUPANT CORY WHO SAYS HE HAD PERMISSION FROM OWNERS DAUGHTER TO RESIDE IN DWELLING, INSPECTOR EXPLAINED THE DWELLING IS STILL CONDEMNED FROM DECEMBER 2019 T19DV09519 AND NO ONE IS ALLOWED TO OCCUPY. CORY ALONG WITH 4 OTHER INDIVIDUALS ARE PACKING THEIR BELONGINGS TO LEAVE THE PROPERTY. DUE TO THE HISTORY AT THE PROPERTY, CE WILL HAVE CITY CONTRACTOR SECURE DWELLING, PROPERTY OWNER WILL BE REQUIRED TO CONTACT CE PRIOR TO ENTERING THE DWELLING FOR ANY REASON. CE INSPECTION WILL BE REQUIRED PRIOR TO ALLOWING FOR FUTURE OCCUPANCY. POSTED PROPERTY WITH "do not occupy" PLACARDS IN FRONT SIDE AND REAR OF DWELLING. INTERIOR STILL HAS ELECTRICAL HAZARDS TO INCLUDE BUT NOT LIMITED TO; EXPOSED WIRING THROUGHOUT DWELLING, 100 AMP SERVICE PANEL HAS MISSING AND BROKEN BRAKERS, DOUBLE LUGGING, UNLABELED DEAD FRONT, ELECTRICAL PANEL BACKER BOARD IS DETERIORATED, SERVICE PANEL IS SUPPLYING POWER FOR 2 COOLER UNITS ON ROOF TOP, 4 WINDOW A/C UNITS. WASHER AND DRYER PLUGGED INTO REG OUTLET HANGING FROM WALL AND ELECTRICAL WIRES, BROKEN AND MISSING OUTLET COVERS AND JUNCTION BOXES, GENERAL DILAPIDATION TO DWELLING INTERIOR AND EXTERIOR, HOLES IN WALLS EXPOSED SUNLIGHT THROUGH WALLS FROM EXTERIOR ALLOWING THE ELEMENTS OF EXTERIOR TO ENTER INTERIOR, ROTTED WOOD FACIA AND OTHER WOOD PORTIONS OF THE ROOF AND DWELLING, POSSIBLE UNPERMITTED ADDTIONS TO DWELLING, OLD PLUMBING FOUND NEAR NEW BATHROOM ADDITION. WILL REQUIRE FULL SET OF PLANS FOR ELECTRICAL, PLUMBING, STRUCTURAL AND MECHANICAL FOR ALL UNAPPROVED WORK. EXTERIOR VIOLATIONS FOUND, OUTDOOR STORAGE, REFUSE AND DEBRIS, INOPERABLE VEHICLES, RV WHICH WAS PLUGGED INTO POWER CORD THAT EXTENDED ALONG THE OUTSIDE OF THE RV TO THE RV ROOF ONTO THE DWELLING ROOF, INTO AN OPENING ON THE ROOF, THE OPENING APPEARS TO BE A SKYLIGHT COVERED WITH A LIGHT WOOD PANEL, HOWEVER NOT SECURED. TOOK PICTURES OF ALL ISSUES, WILL ISSUE NEW NOV FOR INTERIOR AND EXTERIOR VIOLATIONS AND WILL HAND DELIVER NEXT BUSINESS DAY.