Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T20DV04984

Parcel: 126210790

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T20DV04984

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
07/23/2020 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY TFD: THE TWO CAR GARAGE (21.5 X 22) (WOOD FRAME) HAS MAJOR DAMAGE THE ALL CEILING JOINTS, MAIN BEAM AND DECKING, THERE ARE DEEP CRACKS AND AREAS OF THE MEMBERS WHICH ARE CHARRED. THERE ARE MULTIPLE WALL STUDS WITH FIRE DAMAGE. THERE ARE TWO 2 X 4 WINDOWS, TWO MAN DOORS AND THE GARAGE DOOR DAMAGED.
THE HOME HAS THREE EXIT DOORS THAT WERE FORCE OPENED AND WITH BROKEN DOOR JAMS. THE HALLWAY WALL WHICH ABUTS THE GARAGE HAS INSPECTION HOLES.
THE EXTERIOR OF THE GARAGE HAS STUCCO FINISH DAMAGED.


ELECTRICAL: THE INTERIOR OF THE GARAGE HAS BARE, BURNT WIRING. INTERIOR HALLWAY HAS EXPOSED ELECTRICAL CABLES. TEP DID DISCONNECT POWER AT THE TRANSFORMER.



PLUMBING: THE GARAGE HAD A GAS FIRED WATER HEATER WITH GAS FLEX LINE DAMAGED. GAS WAS PINNED OFF.


MECHANICAL: MILD SMOKE DAMAGE TO INTERIOR.


REMARKS: THE HOME WAS CONDEMNED, DUE TO POWER DISCONNECTED. SECURITY CO DICTOGRAPH WILL SECURE THE DAMAGED OPENINGS. PERMIT REQUIRED FOR REPAIRS.