Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T20DV04825
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/31/2022 | INSP - FOLLOW UP CODE ENFORCE | Approved | RESUBMITTAL TO PDSD ,CLOSE CASE | |
04/08/2022 | INSP - FOLLOW UP CODE ENFORCE | Approved | 3RD RESUBMITTAL T21CM04955 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet Zoning and other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. GENERAL COMMENTS: 1. Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Show the as-built addition with necessary alterations for achieving code compliance. FLOOR PLANS: 1. Detail and specify stair width (min 36”, R311.7.1), rise and run (min. 10” tread depth, 7 ¾” max. riser height, R311.7.5), landing width (R311.7.6), handrail height (R311.7.8.1), guardrail height (R312.1) and intermediate rail spacing (R312.2). PLUMBING PLANS: 1. Notate the water heater demand for determining the minimum gas pipe size or circuit size for safely operating the device at full capacity, P2801. ELECTRICAL PLANS: 1. Provide a circuit entry on the panel schedule for the water heater sized for serving the load, E3702.11. Verify or update the 4,500 watt entry on the load calculation. 2. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. 3. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
|
10/19/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | ARCHITECT STATES HE IS WAITING AND STRUCTURAL AND HISTORICAL REVIEW | |
10/14/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | EMAILED ARCHITECT FOR AN UPDATE, I SEE HISTORICAL REQUIRED | |
08/06/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT T21CM04955 IS IN PLAN CHECK WILL EMAIL ARCHITECT FOR AN UPDATE | |
05/21/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | GRANTED 30-DAY FINAL EXTENSION | |
05/19/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | NO ACTIVITY, EMAILED ARCHITECT FOR UPDATE | |
03/18/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | ARCHITECT WORKING ON ENGINEERING CALS FOR SUBMITTAL |