Case: T20DV02847

Parcel: 125074890


Addresses:

2501 E 8TH ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
04/25/2020 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY TFD:THERE IS FIRE DAMAGE TO A 12 X 16 FOOT AN ATTACHED WOOD FRAMED PORCH. THE FOLLOWED STRUCTURAL MEMBERS HAVE DAMAGE AS FAR AS DEEP CRACKS AND ARE BURNT: THE LEDGER BOARD, 12 FOOT OF A 4 X 6 FOOT BEAM, 4 RAFTERS, ONE 4" X 6" POST AND A 2" X 4" FRAMED OUTER WALL. THE DECKING DOES HAVE CRACKING IN THE FIRE ZONE.


ELECTRICAL: THE SPILT METER TYPE MAIN DISCONNECT IS IN CLOSE PROXIMITY TO THE FIRE, TEP DID DISCONNECT POWER.


PLUMBING: SWG DID THERE CHECK AND THE GAS WAS LEFT ON.



MECHANICAL: N/A



REMARKS: THE HOME IS CONDEMNED AND PERMITS ARE REQUIRED FOR REPAIRS. OWNER TO SECURE THE HOME.