Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2020 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE, MET WITH TFD INVESTIGATORS WHO STATED FIRE STARTED IN THE REAR OFFICE, DUE TO A PILE OF RAGS ON THE FLOOR WITH DIFFERENT CHEMICALS (SPONTANEUS COMBUSTION) FINDINGS ARE AS FOLLOWS: ELECTRICAL: >POWER CUT AT THE POLE DUE TO ELECTRICAL METER PANEL FALLING APART WHEN TEP TRYING TO REMOVE THE METER. RECONNECT PERMIT REQUIRED. >FIRE STARTED NEXT TO INTERIOR SUB PANEL, KICKED BREAKERS TO THE SUB PANEL. POSSIBLE DAMAGE TO THE HOME RUNS AT ENTRY TO THE PANEL. >FIRE DAMAGED WIRING, MELTED SWITCHES, OUTLETS AND LIGHT FIXTURES. FRAMING: >FRAMING TO THE FURRED OUT BLOCK WALL WAS FIRE DAMAGED ON THE SOUTH WALL, STUDS BURNED. >LARGE HOLE CUT IN THE ROOF BY TFD APPROX 6FT X 6FT DRYWALL: SOUTH WALL AND ADJOINING EAST AND WEST WALL IN THE AREA HAD FIRE DAMAGED DRYWALL. PLUMBING: WATER LEAKING IN THE WASH TUB AREA, UNABLE TO STOP THE LEAK, ATER TURNED OFF AT THE MAIN. DROPPED CEILING: LARGE PORTION OF THE DROPPED CEILING WAS FIRE DAMAGED, HEAVY SMOKE DAMAGE TO THE PREP AREA AND SERVICE AREAS, WILL REQUIRE REPLACING . NOV ISSUED TO THE RESTARAUNT OWNER AND SIGNED FOR BY THE OWNER. SINGLE DOOR OPENING AND DRIVE THRU WINDOW OPENING WERE SECURED BY ARCADIAN BOARD UP. >TEP CUT POWER TO THE STRUCTURE AT THE POLE >S/W GAS TURNED OFF GAS AT THE METERAND AT INTERIOR GAS CONNECTIONS. >WATER WAS SHUT OFF AT THE MAIN OUTSIDE THE STORE. |