| 03/08/2020 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL OUT BY TFD:THERE IS SEVERE FIRE DAMAGE TO THE FRONT 6' X 30' PORCH AREA. THERE IS FIRE DAMAGE TO THE ALL (14) 2 X 4 ROOF RAFTERS AND DECKING. THE DECKING IS PLANKS. ALL (4) 4 X 4 POST ALSO DAMAGED. ALL (4) BOARDED 3 X 3 WINDOW ALSO FIRE DAMAGED AGAIN FROM THE PREVIOUS FIRE ON 3-05-2020. THE ROOF ASSEMBLY HAS MULTIPLE TRUSSES AND ROOF PLANKING MEMBERS WITH DAMAGE. THERE IS A 3X3 ROOF CUT OUT. THERE IS MAJOR WATER DAMAGE TO THE INTERIOR DRYWALL COVERING, ONE ENTRANCE AREA OF A LIVING ROOM HAS SEVERE DAMAGE TO THE CEILING AND WALLS. ALL OTHER ROOMS ALSO HAVE DAMAGE AND PENETRATIONS TO THE CEILING DRYWALL. ALL STRUCTURAL MEMBERS IN THE DESCRIPTION HAVE DEEP CRACKS WITH THE AREAS OF EXTERIOR TEXTURE CHARRED. ELECTRICAL: THERE ARE MULTIPLE AREAS IN THE ATTIC WITH BARE AND BURNT WIRING ALONG DAMAGED FIXTURES. THE TWO SERVICE DROPS TO THE PROPERTY WERE DISCONNECTED AT THE POLE ON THE LAST FIRE DATE OF 3-05-2020. PLUMBING: NO GAS SERVICE MECHANICAL: HEAVY SMOKE DAMAGE TO THE ENTIRE DWELLING. REMARKS: THIS HOME WAS VACANT NEGLECTED AND BOARDED PRIOR TO THE FIRE. THE CONDEMNATION CONTINUES. PERMITS ARE REQUIRED FOR REPAIRS. THE DAMAGED OPENINGS WILL BE RE SECURED BY BOARDING.THE REAR PERIMETER GATE WAS LOCKED WITH CHAIN AND PAD LOCK, BIFF BAKER DID RESECURE THE REAR DAMAGED FENCE OPENING AND INSTALLED 4 FENCE PANELS TO THE FRONT OF THE PROPERTIES DRIVEWAY. |