Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 09/08/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Add vertical fire blocking every 10' between units. Add anchor bolts 6 - 12" at every break in plate. Missing blocking at 8' - 10'. Loose shear walls. Stopped inspection. 9/8/2023 |
| 09/13/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
Ok to cover exterior walls. |
| 09/22/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|