Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
10/05/2021 REINFORCED MASONRY PRE-GROUT Approved Approved. 20 to 24 feet. Top-out.
10/01/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial. 16 to 20 feet, house wall
09/29/2021 REINFORCED MASONRY PRE-GROUT Partial Approval PA. 4th lift on main house
09/24/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial approval for third lift ok to grout
09/15/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial. First lift. 0 to 4 feet