Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - T20CM08681
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | DMUNIZ | Approved | Entered by NGARCIA3 - corrections required, framing not per plan provide revised set of plans reflecting additional bedroom in garage & added gas fuel fire place prior to finals. Install nail protection where needed, install additional outlets in bathrooms to meet 2’-4’ NEC requirement. Hardwire all exhaust fans. Re locate tv outlet behind fire place to where accessible. |