Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Passed
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 05/24/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
DMUNIZ |
Approved |
Entered by NGARCIA3 - corrections required, framing not per plan provide revised set of plans reflecting additional bedroom in garage & added gas fuel fire place prior to finals. Install nail protection where needed, install additional outlets in bathrooms to meet 2’-4’ NEC requirement. Hardwire all exhaust fans. Re locate tv outlet behind fire place to where accessible. |