Permit: T20CM08143

Parcel: 13819110L


Addresses:

404 W ELVIRA RD 1&2

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/22/2021 PLUMBING - FINAL Approved APPROVED
01/19/2021 PLUMBING - FINAL Denied Denied...... Please see following discrepancies....
1. R602.6.1 Over notched top plates: Code requires 16 gauge strap 6 inches past each side of the over-notched opening, 8 10D nails 1.5 inches long or greater each side.......
2. R315: C/O alarms......
3. G2411.1: Electrical Bonding to gas piping system....
4. Could not verify BTU Rating on exterior WH flex connectors.. size is in question...
5. Seal piping extending through wall...