Permit: T20CM07673

Parcel: 131042640


Addresses:

4901 E 27TH ST

Inspection Status: Passed

Inspection History: COT - RSBU - Preslab  

Date Description Inspector Results Comments
03/30/2021 COT - RSBU - Preslab   RELEFANTE Approved Entered by VLEON1 -
03/26/2021 COT - RSBU - Preslab   WGALLAGHER Not ready for Inspection Entered by VLEON1 - NOT READY CLEAN OUT FOOTERS PLACE REBAR PER PLAN
03/23/2021 COT - RSBU - Preslab   TGAUSP Not ready for Inspection Entered by RSALDAT1 - Not Ready-NR, need to cut additional concrete for foundation
03/16/2021 COT - RSBU - Preslab   WGALLAGHER Denied Entered by RSALDAT1 - Denied Slab was poured prior to inspection and has no footers Cut slab and remove concrete, dig footers place rebar per approved plans, Dowel new slab with #4 rebar epoxied every 2” around perimeter to tie new slab to new footers. Call for inspection prior to doweling and concrete placement.