Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Passed
Inspection History: COT - RSBU - Preslab
| Date |
Description |
Inspector |
Results |
Comments |
| 03/30/2021 |
COT - RSBU - Preslab |
RELEFANTE |
Approved |
Entered by VLEON1 - |
| 03/26/2021 |
COT - RSBU - Preslab |
WGALLAGHER |
Not ready for Inspection |
Entered by VLEON1 - NOT READY CLEAN OUT FOOTERS PLACE REBAR PER PLAN |
| 03/23/2021 |
COT - RSBU - Preslab |
TGAUSP |
Not ready for Inspection |
Entered by RSALDAT1 - Not Ready-NR, need to cut additional concrete for foundation |
| 03/16/2021 |
COT - RSBU - Preslab |
WGALLAGHER |
Denied |
Entered by RSALDAT1 - Denied
Slab was poured prior to inspection and has no footers
Cut slab and remove concrete,
dig footers place rebar per approved plans,
Dowel new slab with #4 rebar epoxied every 2” around perimeter to tie new slab to new footers.
Call for inspection prior to doweling and concrete placement. |