Permit: T20CM07013

Parcel: 11507251G


Addresses:

1410 N ORACLE RD


Inspection Status: Canceled

Inspection History: COT - HCBU - Framing

Permit Number - T20CM07013

Inspection Description - COT - HCBU - Framing

Inspection Status - Canceled

Date Description Inspector Results Comments
11/07/2022 COT - HCBU - Framing Canceled Inspection Canceled
07/25/2022 COT - HCBU - Framing JBURGE Not ready for Inspection Entered by VVERA1 - Not ready. Contractor cancelled
07/07/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - Partial. Level #5; Room units 517; 519; 521; 523. Ok to insulate and cover walls
07/06/2022 COT - HCBU - Framing JBURGE Not ready for Inspection Entered by VVERA1 - Not ready. Contractor cancelled. Will reschedule for 7 July.
07/01/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - Partial. Level #4 East corridor
06/14/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - Partial. Level #3; Units 301 - 324
06/07/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - Partial. Level #4; Units 406, 407, 408, 409, 410, 418, 419, 421, 422
06/03/2022 COT - HCBU - Framing JBURGE Not ready for Inspection Entered by NGARCIA3 - Not ready. Contractor cancelled.
04/26/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - Partial. Level #4; All units exterior walls on interior side. Ok to spray insulate.
04/25/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - Partial. Level #3, Units 301 - 307, 317.
03/29/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - Partial. Level #3, exterior walls. Ok to spray foam insulation.
03/16/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial. Level #5 corridor above ceiling; studs and clips in place.
03/11/2022 COT - HCBU - Framing JBURGE Not ready for Inspection Entered by NGARCIA3 - Not ready. Contractor cancelled
02/24/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial. Pop-out at Levels 2 -4 in South courtyard area. Ok to cover exterior walls.
02/23/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - Partial. Pop-out at NORTHWEST corner of building at Levels 1-5. Ok to cover progress areas.
02/11/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial. Pop-out at Southwest corner of building. Ok to cover progress areas.
02/07/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial. Exterior pop-outs on South side of building. Ok to cover progress areas.
02/03/2022 COT - HCBU - Framing JBURGE Not ready for Inspection Entered by RSALDAT1 - Not ready. Contractor cancelled will reschedule for 7 February.
01/28/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial. Pop-outs (4) on East side and South side. Ok to cover progress areas.
01/26/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial. Two each 6” PVC vent lines for water heaters on Level #2. Extended from Level #2 to Level #3.
01/07/2022 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial. Drain leader pop-outs on East side of building, levels #1 - #3. Ok to cover progress areas.
12/27/2021 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial. Level #1; Units: 108, 109, Laundry Room, 110, 111, 112, 113, 114, 115, 116.
12/15/2021 COT - HCBU - Framing JBURGE Partial Approval Entered by RSALDAT1 - Partial. Level #1; Units #101-107. Exterior roof drains, framing for pop-outs on Level #1.
12/08/2021 COT - HCBU - Framing JBURGE Partial Approval Entered by VVERA1 - Partial, Level #2, corridor ceiling. Ok to cover progress areas.
12/07/2021 COT - HCBU - Framing JBURGE Not ready for Inspection Entered by RSALDAT1 - Not ready. Contractor cancelled. Will reschedule for 8 December.
12/03/2021 COT - HCBU - Framing JBURGE Partial Approval Entered by RSALDAT1 - Partial. Level #1; Room Units 118, 119, 120, 121, 122, 123, 124.
10/29/2021 COT - HCBU - Framing JBURGE Partial Approval Entered by NGARCIA3 - . Partial. Level #1; apartment units with demising walls, screwed in place.
10/20/2021 COT - HCBU - Framing DQUINN Partial Approval Entered by VVERA1 - pa 1st floor corridor lid ok to 5/8 rock underside of floor joists. Clips and Titans ok.