Inspection History Details
Inspection Status: Canceled
Inspection History: COT - HCBU - Exterior Clips/Sheathing
Permit Number - T20CM07013
Inspection Description - COT - HCBU - Exterior Clips/Sheathing
Inspection Status - Canceled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/07/2022 | COT - HCBU - Exterior Clips/Sheathing | Canceled | Inspection Canceled | |
03/07/2022 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by VVERA1 - Partial. Metal roof decking; crickets and roof,drains,in place. Ok to cover roof system. |
03/04/2022 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Not ready for Inspection | Entered by VVERA1 - Not ready. Contractor cancelled; too windy for roof inspection. |
02/24/2022 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by VVERA1 - Partial. Level #4 corridor: clips and Titian bolts in place |
02/11/2022 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by VVERA1 - Partial. Level #2; exterior walls. Ok to spray insulation for interior portion and to cover Effis system. |
01/28/2022 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by VVERA1 - Partial. Exterior sheathing on East wall at Levels #1 - #4. Ok to waterproof progress areas. |
01/18/2022 | COT - HCBU - Exterior Clips/Sheathing | ESTEVENS | Partial Approval | Entered by VVERA1 - Partial. Shearwall. Level 2. From unit 208 to 216 |
01/14/2022 | COT - HCBU - Exterior Clips/Sheathing | ESTEVENS | Cancelled | Entered by NGARCIA3 - Canceled by contractor, Mark. |
12/27/2021 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by VVERA1 - Partial. Level #3; East side of building. Ok to waterproof progress areas. |
12/03/2021 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by RSALDAT1 - Part1al. Exterior sheathing at Level #1. Ok to waterproof progress areas. |
12/01/2021 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by RSALDAT1 - Partial. Information only for exterior sheathing schedule. |
11/30/2021 | COT - HCBU - Exterior Clips/Sheathing | DQUINN | Cancelled | Entered by RSALDAT1 - ca Per Mark |
11/22/2021 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Not ready for Inspection | Entered by RSALDAT1 - . Not ready. Contractor cancelled. |
11/16/2021 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by RSALDAT1 - Partial. East elevation of Level #1. Exterior sheathing (EXP Board). Ok to cover progress area. |
11/12/2021 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by NGARCIA3 - Partial. Interior courtyard at Level #1. Ok to cover exterior walls with EXP Sheathing. |
11/08/2021 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Partial Approval | Entered by VVERA1 - Partial. Level #1, East Section exterior walls; Ok to hang dens glas sheathing 9n progress areas. |
06/28/2022 | COT - HCBU - Exterior Clips/Sheathing | JBURGE | Not Applicable | Entered by NGARCIA3 - N/A. Eephus system in place. No stucco system utilized on this building. |