Permit: T20CM06766

Parcel: 133093520


Addresses:

8075 E HAYDEN PL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T20CM06766

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/07/2020 PLUMBING - FINAL Approved Close permit
10/22/2020 PLUMBING - FINAL Denied de

Temperature- pressure relief valve drain line must be hard piped. Flex pipe cannot be used due to the restricted I.d.
Also, the hard drain line must be pitched for drainage, immediately upon exiting the valve, all the way to its termination point.