Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/11/2021 |
PLUMBING - ROUGH, SOIL |
|
Approved |
Ok to backfill all the way to tie in. |
| 12/24/2020 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
Not Ready, Remove plumbing that is running parallel in exterior footings. Install under slab, test and recall inspection. |