Inspection Status: Not Ready
Inspection History: COT - RSEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
COT - RSEL - Electrical Final |
|
Not Ready |
|
| 02/24/2023 |
COT - RSEL - Electrical Final |
|
Not Ready |
Secure whips on a/c. change out fuses, add cover plate. Lighting above tub needs to be at 8’. Receptacle in laundry room needs to be gfci. A pan is required underneath water heater. Flute vent in laundry room is backwards. Missing hammer arrestor for dishwasher, fridge and laundry room. Clean out needs to be cut to grade level. add elbows to exterior pipes. |
| 03/10/2023 |
COT - RSEL - Electrical Final |
|
Passed |
Light fixture above tub has been raised to 8' above top of tub. GFCI receptacle was installed in mechanical room. |