Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Not Ready
Inspection History: RSBU - Building Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
RSBU - Building Final |
|
Not Ready |
|
| 02/24/2023 |
RSBU - Building Final |
|
Not Ready |
Secure whips on a/c. change out fuses, add cover plate. Lighting above tub needs to be at 8’. Receptacle in laundry room needs to be gfci. A pan is required underneath water heater. Flute vent in laundry room is backwards. Missing hammer arrestor for dishwasher, fridge and laundry room. Clean out needs to be cut to grade level. add elbows to exterior pipes. |
| 03/10/2023 |
RSBU - Building Final |
|
Passed |
Building is complete. Ready for Certificate of Occupancy. |