Inspection Status: Not Ready
Inspection History: COT - RSME - Mechanical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
COT - RSME - Mechanical Final |
|
Not Ready |
|
| 02/24/2023 |
COT - RSME - Mechanical Final |
|
Not Ready |
Secure whips on a/c. change out fuses, add cover plate. Lighting above tub needs to be at 8’. Receptacle in laundry room needs to be gfci. A pan is required underneath water heater. Flute vent in laundry room is backwards. Missing hammer arrestor for dishwasher, fridge and laundry room. Clean out needs to be cut to grade level. add elbows to exterior pipes. |
| 03/10/2023 |
COT - RSME - Mechanical Final |
|
Passed |
Electrical whip conduit is properly secured to wall of house. Water heater pan was installed in mechanical room. |