Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T19RW01282

Parcel: 11006005F


Addresses:

3103 N COLUMBUS BL


Inspection Status: Approved

Inspection History: TDOT-EXCAV GENERAL INSPECTION

Permit Number - T19RW01282

Inspection Description - TDOT-EXCAV GENERAL INSPECTION

Inspection Status - Approved

Date Description Inspector Results Comments
08/19/2019 TDOT-EXCAV GENERAL INSPECTION Approved Completed.
07/16/2019 TDOT-EXCAV GENERAL INSPECTION Continued Asphalt at scupper needs repair. 1 sidewalk panel is cracked and needs to be replaced.
07/02/2019 TDOT-EXCAV GENERAL INSPECTION Continued Poured scupper top and sidewalks to scupper.
07/01/2019 TDOT-EXCAV GENERAL INSPECTION Continued East sidewalks completed. Scupper floor and top poured.
06/25/2019 TDOT-EXCAV GENERAL INSPECTION Continued Review design and layout of sidewalk scupper type 3. Slab of scupper to project to asphalt roadway and lid to be width of sidewalk. Curb at roadway to return to sidewalk.
06/07/2019 TDOT-EXCAV GENERAL INSPECTION Continued East sidewalks formed, grade compacted and poured along with back curb of ADA ramps (2).
06/05/2019 TDOT-EXCAV GENERAL INSPECTION Continued Meeting at job site to review sidewalk layout.
05/30/2019 TDOT-EXCAV GENERAL INSPECTION Continued Called contractor to renew permit.
05/29/2019 TDOT-EXCAV GENERAL INSPECTION Continued No change.
05/15/2019 TDOT-EXCAV GENERAL INSPECTION Continued No change.
05/09/2019 TDOT-EXCAV GENERAL INSPECTION Continued Poured curb at ADA ramps. Paving private roadway.
04/30/2019 TDOT-EXCAV GENERAL INSPECTION Continued Curbs formed at entry.
04/25/2019 TDOT-EXCAV GENERAL INSPECTION Continued Existing curb removed.
04/23/2019 TDOT-EXCAV GENERAL INSPECTION Continued Phone box (old) in conflict with new drive apron and existing depressed curb. Contractor has contacted phone company about moving box but no response.. Contractor will submit shifting the apron 3'-4' to avoid box, this will include replacing depressed curb.
04/22/2019 TDOT-EXCAV GENERAL INSPECTION Continued South sidewalk poured but has section omitted for the scupper, asked contractor to place a 2nd barricade at scupper location.
04/22/2019 TDOT-EXCAV GENERAL INSPECTION Continued Conflict with existing old phone box at existing depressed curb. Contractor to submit revision to shift north 3'-4' the drive apron and replace existing depressed curb. Contractor has requested the phone company to move the box but no response.
04/18/2019 TDOT-EXCAV GENERAL INSPECTION Continued South sidewalk along Blacklidge inspected forms and grades. Expansion jt. material on site. Pour 10:30 today. 1 Tucson Water cathodic station box (traffic rated) in sidewalk near existing HC ramp.
04/17/2019 TDOT-EXCAV GENERAL INSPECTION Continued Precon at 9:45. Review site and specifications. South run of sidewalks ready to pour 4/18.
04/16/2019 TDOT-EXCAV GENERAL INSPECTION Continued Contractor called for precon. Sidewalks. For 4/17 at 9am.
03/12/2019 TDOT-EXCAV GENERAL INSPECTION Not ready for Inspection Pre-con. There will be no work in roadway, contractor will call when ready for inspections.